+Categories
![]() |
A lot of applications are available by various functions of Display Units.
l Corresponds to the RS-485 interface.(Option)
l Real time measurment and Max./Min. value, Average value Display for a period.
l Average,Difference,Sum,Ratio,Flatness calculation of Multi-axis measurement
l Large diameter/Long width measuring
l Film thickness measuring
l IC-Pin Pitches measuring
l Total Control of Multi-production lines
l Cable cover(wall) thickness measuring
l Outside Diameter Control is available by Control Units
l Others
l The measuring instrument of the LASER DIAMETER with the outside diameter control function also did the lineup. ( LDM-210C /LDM-210EXC)
| LDM-210 | LDM-210EXC | ||||||
No. of Axes | For Single | Max. 2 | Max. 5 | Max. 3 | For Single | Max. 2 | ||
Scanning cycle | 400 times/sec | 400 times/sec | 400 times/sec | 400 times/sec | 2000 times/sec or 400 times/sec | |||
No. of | 1-2048 | 1-2048 | 1-2048(22 steps) at LDM-1000LS | 1-2048 | ||||
Averaging time | (16 steps) | (8 steps) | 1-1024(19 steps) at LDM-1000XY | (12 steps) | ||||
Measuring mode | 16 kinds | 8 kinds | 16 kinds + Optional edges measurement | Optional edges measurement | ||||
(X,Y axis each) | per each axis | per each axis | ||||||
Processing | NG | Average, Difference, Large dia. measurement, etc. | NG | Average, Difference, Large dia. measurement, etc. | ||||
function | ||||||||
Cable cover(Wall) | NG | NG | OK(by LDM-1000XY) | NG | ||||
thickness | ||||||||
processing | ||||||||
Display device | 7 segment LED | Graphic LCD | 7 segment LED | 7 segment LED | ||||
No. of Display digit | 4-5 digits | 4-5 digits | 3-6 digits | 3-6 digits | 4-5 digits | |||
Processing | NG | NG | OK | OK | NG | |||
contents monitor | ||||||||
Center position | LED(8pcs) | LED(8pcs) | Graphic bargraph | LED(8pcs) per each axis | LED(8pcs) | LED(15pcs) | LED(8pcs) | |
monitor | (X,Y axis each) | per each axis | (X,Y axis each) | |||||
No. of channel of | 1 | 1 | 1 channel per board(LDM-1000LS/XY) | 1 | ||||
Recorder output | ||||||||
Recorder output | Max.+/-10V, Resolution 12bits(=approx.10mV/1bit), | Max.+/-10V, Resolution 12bits(=approx.10mV/1bit), | ||||||
performance | Output impedance 100ohm(approx.), | Output impedance 100ohm(approx.), | ||||||
| Deviation/Absolute value switch over available | Deviation/Absolute value switch over available | ||||||
Recorder output | 1μm-1m/V(decade steps) | 0.1μm~1m/V(decade steps) | 1μm-1m/V(decade steps) | |||||
gain | ||||||||
Digital dia. | OK | OK | NG | NG | OK | NG | ||
controller | ||||||||
connection |
| |||||||
Center value | 5 digits | 5 digits | 6 digits | 6 digits | 5 digits | |||
setting | ||||||||
High/Lo limit | 4 digits | 4 digits | 6 digits | 5 digits | 5 digits | |||
tolerance setting | ||||||||
High/Low limit | 1a contact(*2) | 1a contact(*2) per board(LDM-1000LS/XY) | 1a contact(*2) | |||||
contact output | Contact rating: AC250V 2A(Resistance load) | Contact rating: AC250V 2A(Resistance load) | ||||||
Error | 1b contact(Close when power OFF) | 1b contact(Close when power OFF)(Combined use by each board) | 1b contact(Close when power OFF) | |||||
contact output | Contact rating: AC250V 2A(Resistance load) | Contact rating: AC250V 2A(Resistance load) | ||||||
Laser remote | OK | OK | OK(each LDM-1000LS board) | OK | OK(X,Y common) | |||
terminal | (X,Y common) |
|
|
| ||||
Hold terminal | OK | OK | OK(each LDM-1000LS/XY board) | OK | OK(X,Y common) | |||
(X,Y,P common) | ||||||||
Edge monitoring | OK | OK | OK | OK | OK | |||
function | ||||||||
Self-diagnosis | OK | OK | OK | OK | OK | |||
mode | ||||||||
Multi-point | OK | NG | NG | NG | OK | |||
calibration | ||||||||
function | ||||||||
Trigger function | NG | NG | OK | OK | NG | |||
(Max. meas., | ||||||||
Deviation meas., | ||||||||
etc.) | ||||||||
Offset | NG | NG | OK | OK | OK(Ver2.15 or more) | NG | ||
function | ||||||||
Zero set | OK | NG | OK | OK | OK | NG | ||
function | ||||||||
mm/inch | NG | NG | OK | OK | NG | |||
changeover | ||||||||
function | ||||||||
Programing | NG | NG | OK(30 kinds) | OK(9 kinds) | NG | |||
function | ||||||||
Graph display | NG | NG | OK | NG | NG | |||
Serial port | OK | OK | OK | OK | OK | |||
BCD output | Option | OK(by LDM-1000BCD) | Option | |||||
RS-485 Function | Option | NG | Option | |||||
Cable length | Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) | Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) | ||||||
Power supply | AC100-240V Free power supply 50/60Hz | AC100-240V Free power supply 50/60Hz | ||||||
Power | less than 11VA | less than 14VA | less than 15VA(only display unit) | less than 15VA | less than 20VA | |||
consumption | less than 8VA(each board) |
|
| |||||
Ambient | Temperature:0-45 degree centigrade, Humidity:35~85%RH(no condensation) | Temperature:0-45 degree centigrade, Humidity:35~85%RH(no condensation) | ||||||
condition | ||||||||
Outside | 144(W) * 72(H) * 191(D)[mm] | 216(W) * 144(H) * 225(D)[mm] | 144(W) * 72(H) * 191(D)[mm] | 144(W) * 72(H) * 241(D)[mm] | ||||
dimension | ||||||||
Weight | Approx. 1.5kg | Approx. 1.6kg | Approx. 4kg (only display unit) | Approx. 1.5kg | Approx. 1.8kg |